The Powershield Defender AVR 2000VA Uninterruptible Power Supply (UPS) is designed to support multiple computers and peripherals, networked PC’s and point of sale systems. In the event of a power outage the UPS will allow continued operation of the PC so that work can be saved and the system can be shutdown safely. Generally, computers need to be shutdown in a specified manner to avoid damaging the software/data that is being used. By using a UPS and the included software a computer can be automatically shutdown safely in the event of a power outage. Backup time up to 40 minutes depending on connected load. Compact design is ideal for under desk operation.
- General
- Capacity: 2000VA / 1200W
- Topology: Line Interactive
- Temperature: 0 – 40°C
- Humidity: 0-90% (RH non-condensing)
- Noise Level: <5dB (no fan)
- Dimensions: 397D x 146W x 205H mm
- Weight: 12.86kg
- Input
- Voltage: 240V ac (nominal)
- Voltage Range: 177-290V ac
- Frequency Range: 50/60Hz ± 5Hz (auto sensing)
- Output
- Output Voltage: 240V ac ± 10%
- Frequency: AC mode tracks utility
- Frequency Range (battery mode): 50Hz or 60Hz ± 1Hz
- Transfer Time: 6ms typical, 10ms max
- Wave Form (battery mode): Simulated sine wave
- Australian Outlets – UPS & Surge Protection: 3
- Australian Outlets – Surge Protection: 3
- Battery
- Battery Type & Number: 12V*9AH (x2)
- Typical Recharge Time: 6 hours recover to 90% capacity
- Backup Time (50% load): 5.5 mins
- Protection
- Full Protection: Overload, discharge and overcharge protection
- Surge Protection: 936 joules / 19500 Amps
- Communications & Management
- Interface: USB Interface
- Software: Powershield Netguard supports – Windows, Linux, Unix & Mac (free download)
- LCD Alarm: AC mode, battery mode, low battery (battery mode), fault, overload
- Audible Alarm: Battery mode, low battery (battery mode), fault, overload
- Compliance
- Safety: EN62040-1-1 2003. IEC60950-1 : 2001
- EMC: EN62040-2 2006, C-tick
- RoHs: Directive 2011/65/EU
Recent
- New Transistor Listing
- COMING SOON – Cel-Fi Roam R41
- Cel-Fi GO G51 Stationary Repeater – 4G and 5G
- Fibre Patch SC APC In Stock
- Sanus Premium Mounting Brackets
- Cel Fi GO 41 Features
- Telstra Signal Booster/Telstra Mobile Booster
- MaxWell Solid State Relays
- Teltonika 4G/LTE Routers
- NEW RUT360
Archives
- September 2023
- June 2023
- May 2023
- September 2022
- August 2022
- May 2022
- January 2022
- October 2021
- September 2021
- August 2021
- July 2021
- June 2021
- November 2020
- September 2019
- August 2019
- July 2018
- June 2018
- April 2018
- March 2018
- February 2018
- January 2018
- September 2017
- August 2017
- July 2017
- June 2017
- March 2017
- November 2016
- October 2016
- September 2016
- July 2016
- May 2016
- March 2016
- February 2016
- November 2015
- August 2015
- May 2015
- April 2015
- February 2015
- September 2014
- August 2014
- July 2014
- November 2013
- October 2013
- August 2013
- July 2013
- May 2013
- April 2013
- March 2013
- February 2013
- January 2013
- December 2012
- November 2012
- October 2012
- August 2012
- July 2012