Fluke 115 Multimeter

Fluke 115 Multimeter
Designed by electricians. Engineered by Fluke.
Compact true-rms meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.
- Large white LED backlight to work in poorly lit areas
- Resistance and continuity
- Min/Max/Average to record signal fluctuations
- CAT III 600 V safety rated
Safety conformance:
All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.
| Specifications |
| Maximum voltage between any terminaland earth ground |
|
| Surge protection |
|
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
|
| Display |
| Digital: |
6,000 counts, updates 4 per second |
|
| Bar graph |
|
33 segments, updates 32 per second |
|
| Operating Temperature |
|
| Storage Temperature |
|
| Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
| Battery Life |
|
400 hours typical, without backlight |
|
| Accuracy Specifications |
| DC millivolts |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
| DC volts |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.00 V / 0.1 V |
| Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
| AC millivolts1 true-rms |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3(500 Hz to 1 kHz) |
|
| AC volts1 true-rms |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.0 V / 0.1 V |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3(500 Hz to 1 kHz) |
|
| Continuity |
| Range: |
600 Ω |
| Resolution: |
1 Ω |
| Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. |
|
| Ohms |
| Range/Resolution: |
600.0 Ω / 0.1 Ω |
| Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
| Accuracy: |
0.9 % + 1 |
| Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
| Accuracy: |
1.5 % + 2 |
|
| Diode Test |
| Range/Resolution: |
2.00 V / 0.001 V |
| Accuracy: |
0.9% + 2 |
|
| Capacitance |
| Range/Resolution: |
1000 nF / 1 nF |
| Range/Resolution: |
10.00 µF / 0.01 µF |
| Range/Resolution: |
100.0 µF / 0.1 µF |
| Range/Resolution: |
9999 µF / 1 µF |
| Range/Resolution: |
100 µF to 1000 µF |
| Accuracy: |
1.9% + 2 |
| Range/Resolution: |
> 1000 µF |
| Accuracy: |
5% + 20% |
|
| Lo-Z Capacitance |
| Range: |
1 nF to 500 µF |
| Accuracy: |
10% + 2 typical |
|
| AC amps true-rms (45 Hz to 500Hz) |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.5% + 3 |
|
20 A overload for 30-seconds max |
|
| DC amps |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.0% + 3 |
|
20 A overload for 30-seconds max |
|
| Hz (V or A input)2 |
| Range/Resolution: |
99.99 Hz / 0.01 Hz |
| Range/Resolution: |
999.9 Hz / 0.01 Hz |
| Range/Resolution: |
9.999 kHz / 0.001 kHz |
| Range/Resolution: |
50 kHz / 0.01 kHz |
| Accuracy: |
0.1% + 2 |
|
4